Page 1047 - Softbound_Edition_19_en
P. 1047

Proportional pressure reducing valve
                                                                               Proportional pressure reducing valve


            PERFORMANCE SPECIFICATIONS  EXECUTION L9 (MEASURED AT 40 °C)
            Oil viscosity u = 30 mm /s
                             2
             p  = f (Q)  Pressure volume flow characteristics     p  = f (n)  Pressure adjustment characteristics
                                                                   red
              red
                       Maximal adjustable pressure                          Measured at Q = 1 l/min
                 p [bar]                                              p [%]
              400  K0435_1                                         100  K1005
              300                                    P N red = 280 bar  80
                                                                    60
              200                                    P N red = 220 bar
                                                     P N red = 160 bar  40
              100                                    P N red = 80 bar  20
                                                     P N red = 50 bar
                0                                    P N red = 20 bar  0
                 60    40    20    0    20    40   60                  0     20     40    60     80     100 l [%]
                        A     T  Q [l/min]  P   A


             p  = f (Q)  Pressure volume flow characteristics     Q  = f (p)  Leakage volume flow characteristic
              red                                                  L
                       Minimal adjustable pressure                          A (1) → T (3) (pressure in P (2) = 350 bar)
                       *Consumer resistance depending on the system  Q [cm /min]
                                                                          3
                p [bar]  a: P N red = 160/220/280 bar  b: P N red = 20/50/80 bar  1000  K0760_1
               40  K0443_1                                         800
                     a
               30                                                  600
                    b
               20                                                  400
                                                                   200
               10                              ∗
                                                                     0
                                                                           50
                                                                               100
                0                                                      0  P N red = 20/50/80 bar  150  200  250  300  350 p [bar]
                 60    40   20    0     20   40    60                    P N red = 160/220/280 bar
                        A     T  Q [l/min]  P   A

            PERFORMANCE SPECIFICATIONS  EXECUTION L15 / L17 (MEASURED AT 50 °C)
                             2
            Oil viscosity u = 30 mm /s
             p  = f (Q)  Pressure volume flow characteristics     p  = f (n)  Pressure adjustment characteristics
              red                                                  red
                       Maximal adjustable pressure                          Measured at Q = 1 l/min
                 p [bar]                                              p [%]
              400  K0434                                           100  K1002
                                                     P N = 350 bar
              300                                                   80
                                                     P N = 275 bar
                                                                    60
              200                                    P N = 200 bar
                                                                    40
              100                                    P N = 100 bar  20
                                                     P N = 63 bar
                0                                    P N = 20 bar    0
                 60    40    20    0    20    40   60                  0     20     40    60     80     100 l [%]
                        A     T  Q [l/min]  P   A


             p  = f (Q)  Pressure volume flow characteristics     Q  = f (p)  Leakage volume flow characteristic
              red                                                  L
                       Minimal adjustable pressure                          A (1) → T (3) (pressure in P (2) = 350 bar)
                       *Consumer resistance depending on the system  Q [cm /min]
                                                                          3
                p [bar]                                           1000  K0760_2
               40  K0443_2  a: P N red = 200/275/350 bar  b: P N red = 20/63/100 bar  800
                     a
               30                                                  600
                    b
               20                                                  400
                                                                   200
               10                              ∗
                                                                     0
                                                                               100
                                                                           50
                0                                                      0  P N red = 20/63/100 bar  150  200  250  300  350 p [bar]
                 60    40   20    0     20   40    60                    P N red = 200/275/350 bar
                        A     T  Q [l/min]  P   A


                               www.wandfluh.com  Illustrations are not binding  Data subject to change  3/4  Edition: 19 19  2.3-635 E
                                                                                                           Page 1047