Page 1043 - Softbound_Edition_19_en
P. 1043

40
 21, 22
 X2
 83
 X4 (Nur Regler)
       (controller only)
 15
 A(1)
 35
 17.5
 P(2)
 T(3)
 s30
 17
 18
 20
 135
 X1
 X3
 83
 X3
 X4
 17.5
 T(3)
 90 X1 35  X2  95  195  s30  M22x1.5  25, 30 60 M22x1.5  P(2) 50 60 60 A(1) 80  70  90  101  17.5  X1  X2
 150
 Proportional                                                                                         Proportional-
                                                                                           pressure reduced valves
 pressure reduced valves                                                       Proportional pressure reducing valve
 SYMBOL  CONNECTOR WIRING DIAGRAM  INBETRIEBNAHME
 A(1)  Analog interface:  For DSV amplifiers as a rule no parameter settings by the customer   Additional information can be found on our website:
            are required. The plugs have to be connected in accordance with the   «www.wandfluh.com»
 Device receptacle (male) X1  chapter «Pin assignment».
 1  =  Supply voltage +  Controllers will be supplied configurated as amplifiers. Switching into   Free-of-charge download of the «PASO»-software and the instruction
 8 9  1  2  =  Supply voltage 0 VDC  controller mode and setting of the adjustments of the controller must   manual for the «DSV» hydraulic valves as well as the operation instruc-
                                                                 tion CANopen protocol eg. Profibus DP protocol with device profile
 3  =  Stabilisierte Ausgangsspannung
 7 12 10 2  4  =  Stabilised output voltage  be done by the customer using the set-up software (USB interface, Mini B).  DSP-408 for «DSV».
 8 9  1  6  11 3  4  =  Preset value voltage +
 8 9
 P(2)  T(3)  7 12 10 2  5  4  5  =  Preset value voltage - 1
 7 12 10 2
 HYDRAULIC SPECIFICATIONS  6  11 3  6  =  Preset value current  +
 11 3
 6
 Fluid   Mineral oil, other fluids on request 5  4  7  =  Preset value current  -  CHARACTERISTICS  Oil viscosity ν = 30 mm /s
                                             2
 4
 5
 Contamination efficiency  ISO 4406:1999, class 18/16/13  8  =  Reserved for extensions
    (Required filtration grade β 6…10 ≥ 75)  9  =  Reserved for extensions   p  = f (Q)   Pressure volume flow characteristics   p  = f (Q)   Pressure volume flow characteristics
             red
                                                                  red
    refer to data sheet 1.0-50/2  2  3  10 =  Enable control (Digital input)      (Maximal adjustable pressure)     (Minimal adjustable pressure)
 Viscosity range   12 mm /s…320 mm /s  1 5  4  11 =  Error signal (Digital output)      ٭ Consumption resistance dependent on system
 2
 2
 Fluid temperature   -20…+70 °C  2  3  12 =  Chassis  2  3  p [bar]  p [bar]  a: P N red =  160/200/275/350 bar  b: P N red =  20/63/100 bar
 Peak pressure   p max   = 400 bar  5  Preset value voltage (PIN 4/5) resp. current (PIN 6/7) are selected with   400  K0434_1  40  K0443_2  a
 8 9
 1
 5
 4
 1
 Nominal pressure ranges  p N red  =  20 bar, 63 bar, 100 bar, 160 bar,   set-up and diagnosis software PASO.  1  4  P N red = 350 bar
 7 12 10 2
 200 bar, 275 bar, 350 bar  Factory setting: Voltage (0…+10 V), (PIN 4/5)  300  P N red = 275 bar  30  b
 Volume flow range   Q = 0…60 l/min  6  11 3  200   P N red = 200 bar  20
 5
 4
 Pilot- and leakage  Fieldbus interface:
 volume flow   see characteristics  100             P N red = 100 bar  10                          ∗
 1
 2
 1
 2
 Repeatability   ≤ 2 % ∗  Device receptacle supply (male) X1  P N red = 63 bar
 Hysteresis   ≤ 4 % ∗  3 5  4  MAIN  0              P N red = 20 bar  0
 3
 4
    ∗ at optimal dither signal  2  1  2 2  3 1  1 = Supply voltage +  60  40  20  0  20  40  60  60  40  20  0  20  40  60
 5  5  2 = Reserved for extensions  2  1  2  1  A     T  Q [l/min]  P   A  A     T  Q [l/min]  P   A
 ELECTRICAL SPECIFICATIONS  3  4  3 1  4 4  3 = Supply voltage  0 VDC  3 5  4  3  4
 Protection class   IP 67 acc. to EN 60 529  4 = Chassis  p  = f (l)   Pressure adjustment characteristics   Q st + L  = f (p)  Pilot- and leakage volume flow characteristic [A (1) → T (3)]
             red
    with suitable connector and closed      [at Q = 0 l/min]/(s corresponds to preset value signal)      (Pressure in P (2) = 350 bar)
    electronic housing     Inlet pressure: p  +10 %
                                  N
 Supply voltage   12 VDC or 24 VDC  Device receptacle   Device receptacle     Mesured with closed port A
 3
 2
 Ramps (amplifier only)   separate adjustment for up and   CANopen (male) X3   Profibus (female) X3  p [bar]  Q [cm /min]
                                                                         3
 5
    down for each solenoid  2  3     1  4  CAN   PROFIBUS  120  K0764_3  1000  K0760_1
 Preset value generator   preset value speed adjustable   5    2  1  1 = not connected   2  3  1 = VP  P N = 100 bar
 1
 2
 (controller only)  1  4     5  2 = not connected   5  2 = RxD / TxD - N  90  800
 Parameterisation   via fieldbus or USB  3  4  3 = CAN Gnd  4  1  4  600
 3
 Interface   USB (Mini B) for parameterisation     3 = DGND  60  P N = 63 bar
    with «PASO»     4 = CAN High   4 = RxD / TxD - P               400
    (under the closing screw of the housing cover,      8 9  1 5 = CAN Low   5 = Shield  30
    Preset ex-works)  7 12 10 2                     P N = 20 bar   200
 Analog interface (MAIN):   Parameterisation interface (USB, Mini B) X2  0    0
 11 3
 6
                                                                          50
                                                                               100
 Device receptacle (male)  M23, 12-poles  Under the closing screw of the housing cover  0   10  20  30  40 50 60 70 80 90  100 s [%]  0  P N red = 20/63/100 bar  150  200  250  300  350 p [bar]
 4
 5
 Mating connector   Plug (female), M23, 12-poles  2  3                  P N red = 160/200/275/350 bar
    (not incl. in delivery)  Feedback signal interface (Sensor)  p  = f (l)   Pressure adjustment characteristics
             red
 5
 Preset value signal:   Input voltage / current as well as signal   1  4     [at Q = 0 l/min]/(s corresponds to preset value signal)
    range can be set by software.  Device receptacle (female) X4 (only controller)     Inlet pressure: p N  +10 %
 Fieldbus interface:  2  3  1 = Supply voltage (output) +     Mesured with closed port A
 Device receptacle  5  2 = Feedback signal +  p [bar]
 supply (male)   M12, 4-poles  1  4  3 = Supply voltage 0 VDC  400  K0764_2
 Mating connector   Plug (female), M12, 4-poles  4 = not connected  P N red = 350 bar
    (not incl. in delivery)  5 = stab. output voltage  300
 Device receptacle                                  P N red = 275 bar
 CANopen (male)   M12, 5-poles (acc. to DRP 303-1)  200  P N red = 200 bar
 Mating connector   Plug (female), M12, 5-poles  NOTE!  P N red = 160 bar
    (not incl. in delivery)  100
 Device receptacle  The mating connectors and the cable to adjust the set-
 1
 2
 Profibus (female)   M12, 5-poles, B-coded (acc. to IEC 947-5-2)  2  1  tings are not part of the delivery. Refer chapter «Ac-  0  
 Mating connector   Plug (male), M12, 5-poles, B-coded  5  cessories».  0   10  20  30  40 50 60 70 80 90  100 s [%]
    (not incl. in delivery)  3  4  3  4  Factory settings:
 Preset value signal:   Fieldbus
            Dither set for optimal hysteresis
 Feedback signal interface (Sensor):     = Deadband: Solenoid switched off

 (controller only)        with command preset value signal < 5 %
 Device receptacle (female) M12, 5-poles     = Regulated pressure in port A (1) at 70 % of preset value signal::
 Mating connector   Plug (male), M12, 5-poles  250 bar with pressure range 350 bar
    (not incl. in delivery)  2  3  192 bar with pressure range 275 bar
 Feedback signal::   Voltage / current state when ordering  5  143 bar with pressure range 200 bar
 1  4           112 bar with pressure range 160 bar
 NOTE!            72 bar with pressure range 100 bar
 Detailed electrical characteristics and description of     45 bar with pressure range   63 bar
 «DSV» electronics are shown on data sheet 1.13-76.       14,5 bar with pressure range   20 bar
 Wandfluh AG   Tel.  +41 33 672 72 72   E-mail:  sales@wandfluh.com   Illustrations not obligatory   Data sheet no.  Wandfluh AG   Tel.  +41 33 672 72 72   E-mail:  sales@wandfluh.com   Illustrations not obligatory   Data sheet no.
 Postfach   Fax  +41 33 672 72 12   Internet:  www.wandfluh.com   Data subject to change   2.3-632E 2/4  Postfach   Fax  +41 33 672 72 12   Internet:  www.wandfluh.com   Data subject to change   2.3-632E 3/4
 CH-3714 Frutigen                   Edition 17 01  CH-3714 Frutigen                                      Edition 17 01
                                                                                                           Page 1043
   1038   1039   1040   1041   1042   1043   1044   1045   1046   1047   1048