       TYPE CODE                                                                                                                   PERFORMANCE SPECIFICATIONS  EXECUTION L9 (MEASURED AT 40 °C)
                                                                                                                                                    2
                                                               M  V  B  PM22  -     -     /     /     -        #                   Oil viscosity u = 30 mm /s
       Pressure reducing valve                                                                                                      p  = f (Q)  Pressure volume flow characteristics     p  = f (n)  Pressure adjustment characteristics
                                                                                                                                     red
                                                                                                                                                                                          red
       Pilot operated                                                                                                                         Maximal adjustable pressure                          Measured at Q = 1 l/min
                                                                                                                                        p [bar]                                              p [%]
       Proportional, explosion proof execution Ex d                                                                                  400  K0435_1                                         100  K1005
       Screw-in cartridge M22 x 1,5                                                                                                  300                                    P N red = 280 bar  80
                                                                                                                                                                                           60
       Execution                   L9                L15 / L17                                                                       200                                    P N red = 220 bar  40
                                                                                                                                                                            P N red = 160 bar
       Nominal pressure range p N red  [bar]    20   160  20   200
                                   50      220         63      275                                                                   100                                    P N red = 80 bar  20
                                   80      280  100            350                                                                     0                                    P N red = 50 bar  0
                                                                                                                                                                            P N red = 20 bar
                                                                                                                                        60    40    20    0    20    40   60                  0     20     40     60    80     100 l [%]
       Nominal voltage U      12 VDC       G12                                                                                                 A     T  Q [l/min]  P   A
                   N
                              24 VDC       G24

                                                  Ambient temperature up to:                                                        p  = f (Q)  Pressure volume flow characteristics     Q  = f (p)  Leakage volume flow characteristic
                                                                                                                                                                                          L
                                                                                                                                     red
       Nominal power P        9 W          L9     40 °C or 90 °C                                                                              Minimal adjustable pressure                          A (1) → T (3) (pressure in P (2) = 350 bar)
                  N
                              15 W         L15    70 °C                                                                                       *Consumer resistance depending on the system  Q [cm /min]
                                                                                                                                                                                                 3
                              17 W         L17    70 °C (only UL / CSA)
                                                                                                                                       p [bar]  a: P N red = 160/220/280 bar  b: P N red = 20/50/80 bar  1000  K0760_1
       Certification          ATEX, IECEx, EAC,                                                                                       40  K0443_1  a                                      800
                              CCC                 UL / CSA     UL                                                                                                                         600
                              Australia    AU     MA           MA                                                                     30   b
                                                                                                                                      20                                                  400
       Sealing material       NBR                                                                                                                                                         200
                              FKM (Viton)   D1                                                                                        10                              ∗
                                                                                                                                                                                            0
                                                                                                                                                                                                      100
                                                                                                                                                                                                  50
       Options                without                                                                                                  0                                                      0  P N red = 20/50/80 bar  150  200  250  300  350 p [bar]
                              amplifier    M248                                                                                         60    40   20    0     20   40    60                    P N red = 160/220/280 bar
                                                                                                                                               A     T  Q [l/min]  P   A
       Design index (subject to change)
       2.3-635                                                                                                                     PERFORMANCE SPECIFICATIONS  EXECUTION L15 / L17 (MEASURED AT 50 °C)
                                                                                                                                   Oil viscosity u = 30 mm /s
                                                                                                                                                    2
       ELECTRICAL SPECIFICATIONS                           HYDRAULIC SPECIFICATIONS
                                                                                                                                    p  = f (Q)  Pressure volume flow characteristics     p  = f (n)  Pressure adjustment characteristics
       Protection class   IP65 / 66 / 67                    Working pressure   p  = 400 bar                                          red      Maximal adjustable pressure                 red      Measured at Q = 1 l/min
                                                                                max
       Relative duty factor  100 % DF                       Nominal pressure   Execution L9                                             p [bar]
       Voltage tolerance  ± 10 % with regard to nominal voltage  range         p N red  = 20; 50; 80; 160; 220; 280 bar              400  K0434                                           100 p [%]
                                                                                                                                                                                              K1002
       Standard nominal   12 VDC, 24 VDC                                       Execution L15 / L17                                                                          P N = 350 bar  80
       voltage                                                                 p N red  = 20; 63; 100; 200; 275; 350 bar             300                                    P N = 275 bar  60
       Limiting current at… °C L9, 40 °C                    Volume flow range  Q = 0…60 l/min                                        200                                    P N = 200 bar
                          I  = 625 mA (12 VDC)              Leakage oil        See characteristics                                   100                                    P N = 100 bar  40
                           G
                          I  = 305 mA (24 VDC)              Hysteresis         ≤ 5 % at optimal dither signal                                                               P N = 63 bar   20
                           G
                          L15 / 17, 50 °C                   Repeatability      ≤ 2 % at optimal dither signal                          0                                    P N = 20 bar    0
                                                                                                                                                          0
                                                                                                                                                                     40
                                                                                                                                                    20
                          I  = 950 mA (12 VDC)              Fluid              Mineral oil, other fluid on request                      60    40 A     T  Q [l/min]  20 P   A  60           0     20     40     60    80     100 l [%]
                           G
                          I  = 450 mA (24 VDC)              Viscosity range    12 mm /s…320 mm /s
                                                                                   2
                                                                                            2
                           G
                          L15 / 17, 70 °C                   Temperature range   Operation as T6
                          I  = 910 mA (12 VDC)              fluid              NBR -25…+40 °C (L9)                                  p  = f (Q)  Pressure volume flow characteristics     Q  = f (p)  Leakage volume flow characteristic
                                                                                                                                                                                          L
                                                                                                                                     red
                           G
                          I  = 420 mA (24 VDC)                                                                                                Minimal adjustable pressure                          A (1) → T (3) (pressure in P (2) = 350 bar)
                           G                                                   FKM -20…+40 °C (L9)                                            *Consumer resistance depending on the system
                                                                                                                                                                                                 3
       Standard nominal   9 W, 15 W, 17 W                                      Operation as T4                                                                                              Q [cm /min]
       power                                                                   NBR -25…+70 °C (L9 or L15 / L17)                        p [bar]  a: P N red = 200/275/350 bar  b: P N red = 20/63/100 bar  1000  K0760_2
       Temperature class  Nominal power 9 W: T1…T6                             FKM -20…+70 °C (L15 / L17)                             40  K0443_2  a                                      800
                          Nominal power 15 W / 17 W: T1…T4                     FKM -20…+70 °C (L9)                                    30                                                  600
       Note!   Other electrical specifications see data sheet 1.1-183   Contamination   Class 18 / 16 / 13                            20   b                                              400
               and 1.1-184                                  efficiency                                                                                                                    200
                                                            Filtration         Required filtration grade ß 6…10 ≥ 75,                 10                              ∗                    0
                                                                               see data sheet 1.0-50                                   0                                                      0   50  100  150  200  250  300  350 p [bar]
                                                                                                                                        60    40   20    0     20   40    60                    P N red = 20/63/100 bar
                                                                                                                                                                                                P N red = 200/275/350 bar
                                                                                                                                               A     T  Q [l/min]  P   A