Page 911 - Softbound_Edition_19_en
P. 911

Pressure reducing valve
                                                                                           Pressure reducing valve


            Pressure reducing cartridge
             ◆  direct operated                                  7 ⁄8 “-14 UNF
             ◆  p  = 350 bar                                     Wandfluh standard
                max
             ◆  p N red max  = 200 bar
             ◆  Q  = 20 l/min
                max







            DESCRIPTION                                          APPLICATION
            Direct operated pressure reducing valve in screw-in cartridge   The integrated pressure relief makes an additional pressure relief
            construction  for  cavity  according  to  Wandfluh  standard.  The   valve  in  the  consumer  line  superfluous.  In  the  case  of  several
            valve reduces the input pressure to an adjustable output pres-  consumers, the pressure of the specific consumers can be indivi-
            sure. Through the integrated pressure relief function, exceeding   dually adjusted by the pressure reducing valve. Pressure reducing
            the reduced pressure as a result of external forces is avoided.   valves are used  to maintain the pressure in a consumer constant
            The  pressure reducing valve controls the pressure in port A (1).   independent  of  pressure  fluctuations  on  the  supply  side.    The
            Through increasing the spring tension, the pressure in port A(1)   screw-in cartridge is perfectly suitable for installation in control
            rises.  The valve operates practically independently of the pres-  blocks. For machining the cartridge cavity in steel and aluminum
            sure in port P (2). Pressure increase in port A (1) to above the   blocks, cavity tools are available (hire or purchase). Please refer to
            adjusted value, e.g. through an active consumer, is avoided by   the data sheets in register 2.13.


            discharging excess oil to the tank (3).



            SYMBOL                                               ACTUATION
                                                                  Actuation          S = lockable key adjustment
                  (A) 1                                                              D = lockable control knob adjustment





              (P) 2  (T) 3




            TYPE CODE
                                                                                         M  D     PU10  -     -     #
             Pressure reducing valve

             Direct operated
             Type of adjustment     Key             S
                                    Control knob    D

             Screw-in cartridge 7/8“ - 14 UNF

             Nominal pressure range p N   80 bar    80
                                    200 bar        200
             Sealing material       NBR
                                    FKM (Viton)     D1

             Design index (subject to change)
             2.2-550








                               www.wandfluh.com  Illustrations are not binding  Data subject to change  1/3  Edition: 17 27  2.2-550 E