Proportional pressure reducing valve



                                                                                                                                   Proportional pressure reducing cartridge
                                                                                                                                    ◆  direct operated                                  M16 x 1,5
                                                                                                                                    ◆  Q  = 6 l/min                                     Wandfluh standard
                                                                                                                                       max
                                                                                                                                    ◆  p  = 210 bar (350 bar)                           x II 2 G Ex db IIC T6, T4
                                                                                                                                       max
                                                                                                                                    ◆  p    = 100 bar
                                                                                                                                       N red max
                                                                                                                                                                                        x II 2 D Ex tb III C T80 °C, T130 °C
                                                                                                                                                                                        x I M2 Ex db I Mb
                                                                                                                                                                                        Class I Division 1
                                                                                                                                                                                        Class I Zone 1


                                                                                                                                   DESCRIPTION                                          APPLICATION
                                                                                                                                   Direct operated proportional pressure reducing valve in screw-in   These  valves  are  suitable  for  applications  in  explosion-hazard
                                                                                                                                   cartridge construction for cavity according to Wandfluh standard.   areas, open cast and also in mines. The electrical remote control in
                                                                                                                                   Proportionally to the solenoid current, the solenoid force and the   conjunction  with  process  controls  allows  economical  solutions
                                                                                                                                   pressure  in  port  A  (1)  rise.  The  valve  functions  practically  inde-  with repeatable processes. For machining the cartridge cavity in
                                                                                                                                   pendently of the pressure in port P (2). Pressure increase in the   steel  and  aluminum  blocks,  cavity  tools  are  available  (hire  or
                                                                                                                                   consumer port A (1) to above the adjusted value, e.g. through an   purchase). Please refer to the data sheets in register 2.13.

                                                                                                                                   active consumer, is avoided by discharging excess oil to the tank T
                                                                                                                                   (3). With the solenoid deenergised, the oil flows freely from consu-
                                                                                                                                   mer port A (1) to port T (3). For the control, Wandfluh proportional
                                                                                                                                   amplifiers  are  available  (see  register  1.13).  The  pressure  tight
                                                                                                                                   encapsulated Ex-protection solenoid coil prevents an explosion on
                                                                                                                                   the inside penetrating to the outside as well as an ignitable surface
                                                                                                                                   temperature.

                                                                                                                                   SYMBOL                                               CERTIFICATES
                                                                                                                                                                                                      Surface   Mining  Standard   M248
                                                                                                                                         (A) 1                                                                           -25 °C   Electronic
                                                                                                                                                                                                                          to…
                                                                                                                                                                                         ATEX           x         x        x        x
                                                                                                                                                                                         IECEx          x         x        x        x
                                                                                                                                     (P) 2  (T) 3
                                                                                                                                                                                         CCC            x         x        x        x
                                                                                                                                                                                         EAC            x         x        x        x
                                                                                                                                                                                         Australia      x         x        x
                                                                                                                                                                                         MA                       x        x        x
                                                                                                                                                                                         UL / CSA       x                  x
                                                                                                                                                                                        The certificates can be found on www.wandfluh.com



                                                                                                                                   GENERAL SPECIFICATIONS                               ACTUATION
                                                                                                                                    Designation        Proportional pressure reducing valve  Actuation      Proportional solenoid, wet pin push
                                                                                                                                    Construction       Direct operated                                      type, pressure tight
                                                                                                                                    Mounting           Screw-in cartridge construction   Execution          MKY45 / 18x60 (data sheet 1.1-183)
                                                                                                                                    Nominal size       M16 x 1,5 according to Wandfluh                      MKU45 / 18x60 (data sheet 1.1-184)
                                                                                                                                                       standard                          Connection         Cable gland for cable Ø 6,5…14 mm
                                                                                                                                    Actuation          Proportional solenoid            Attention!  The UL execution is always supplied without cable
                                                                                                                                    Ambient temperature  Operation as T4                         gland
                                                                                                                                                       -25…+70 °C (L15 / L17)
                                                                                                                                    Weight             2,2 kg
                                                                                                                                    MTTFd              150 years







                                                                                                                                                      www.wandfluh.com  Illustrations are not binding  Data subject to change  1/4  Edition: 21 21  2.3-608 E