Page 954 - Softbound_Edition_19_en
P. 954

Proportional pressure relief valve
                                                                             Proportional pressure relief valve                                                                                           Proportional pressure relief valve


       CERTIFICATES                                        SYMBOL                                                                  PERFORMANCE SPECIFICATIONS  EXECUTION L9 (MEASURED AT 40 °C)
                                                                                                                                                    2
                    Surface   Mining   Standard  M248                                                                              Oil viscosity u = 30 mm /s
                                        -25 °C   Electronic       (T) 2                                                             p  = f (Q)  Pressure volume flow characteristics     p  = f (n)  Pressure volume flow characteristics
                                                                                                                                                                                          red
                                                                                                                                     red
                                        to…                                                                                                   Maximal adjustable pressure                          Minimum adjustable pressure
       ATEX            x        x         x        x                                                                                    p [bar]                                             p [bar]
       IECEx           x        x         x        x                                                                                 400  K0227                                            40  K0228
                                                                  (P) 1
       CCC             x        x         x        x                                                                                 300                   P N  = 280 bar    P N  = 220 bar    30                                P N  = 160/220/
                                                                                                                                                                                                                                         280 bar
       EAC             x        x         x        x                                                                                                                                                                             P N  = 20/50/
                                                                                                                                     200                                    P N  = 160 bar    20                                         80 bar
       Australia       x        x         x                                                                                                                                 P N  = 80 bar
       MA                       x         x        x                                                                                 100                                    P N  = 50 bar    10
       UL / CSA        x                  x                                                                                            0                                    P N  = 20 bar    0
                                                                                                                                         0       25      50       75      100 Q [l/min]      0       25       50      75      100 Q [l/min]
       The certificates can be found on www.wandfluh.com

       GENERAL SPECIFICATIONS                              HYDRAULIC SPECIFICATIONS                                                 p  = f (n)  Pressure adjustment characteristics      Δp = f (Q)  Leakage volume flow characteristics
                                                                                                                                     red
                                                                                                                                              Measured at Q = 1 l/min
                                                                                                                                                                                                 3
       Designation        Proportional pressure relief valve  Working pressure  p  = 400 bar                                                                                                Q [cm /min]
                                                                                max                                                                                                       250  K0223
       Construction       Pilot operated                    Nominal pressure   Execution L9                                             p [%]
                                                                                                                                         K0226_1
       Mounting           Screw-in cartridge construction   range              P  = 20 bar, 50 bar, 80 bar, 160 bar, 220             100                                                  200
                                                                                N
       Nominal size       M22 x 1,5 according to ISO 7789                      bar, 280 bar                                           80                                                  150
       Actuation          Proportional solenoid                                Execution L15 / 17                                     60                                                  100
       Ambient temperature  Operation as T6                                    P  = 20 bar, 63 bar, 100 bar, 200 bar, 275             40                                                   50
                                                                                N
                          -25…+40 °C (L9)                                      bar, 350 bar                                           20                                                    0
                          Operation as T4                   Volume flow range  Q = 0,3...100 l/min                                     0                                                      0   50  100  150  200  250  300  350 p [bar]
                          -25…+90 °C (L9)                   Leakage oil        See characteristics                                       0     20     40     60     80    100  I [%]
                          -25…+70 °C (L15 / L17)            Hysteresis         ≤ 5 % at optimal dither signal
       Weight             1,9 kg                            Repeatability      ≤ 2 % at optimal dither signal
       MTTFd              150 years                         Fluid              Mineral oil, other fluid on request                 PERFORMANCE SPECIFICATIONS  EXECUTION L15 / L17 (MEASURED AT 50 °C)
                                                            Viscosity range    12 mm /s…320 mm /s                                  Oil viscosity u = 30 mm /s
                                                                                   2
                                                                                            2
                                                                                                                                                    2
                                                            Temperature range   Operation as T6                                     p  = f (Q)  Pressure volume flow characteristics     p  = f (n)  Pressure volume flow characteristics
                                                            fluid              NBR -25…+40 °C (L9)                                   red      Maximal adjustable pressure                 red      Minimal adjustable pressure
                                                                               FKM -20…+40 °C (L9)
       ELECTRICAL SPECIFICATIONS                                               Operation as T4                                       400 p [bar]           P N  = 350 bar                  40 p [bar]
                                                                                                                                         K0224
                                                                                                                                                                                              K0225
                                                                               NBR -25…+70 °C (L9 or L15 / L17)
       Protection class   IP65 / 66 / 67                                       FKM -20…+70 °C (L15 / L17)                            300                                    P N  = 275 bar    30                                 P N  = 200/275/
                                                                                                                                                                                                                                         350 bar
       Relative duty factor  100 % DF                                          FKM -20…+70 °C (L9)                                                                          P N  = 200 bar                                       P N  = 20/63/
       Voltage tolerance  ± 10 % with regard to nominal voltage  Contamination   Class 18 / 16 / 13                                  200                                    P N  = 100 bar    20                                         100 bar
       Standard nominal   12 VDC, 24 VDC                    efficiency                                                               100                                    P N  = 63 bar    10
       voltage                                              Filtration         Required filtration grade ß 6…10 ≥ 75,                  0                                    P N  = 20 bar    0
       Limiting current at… °C L9, 40 °C                                       see data sheet 1.0-50                                     0       25      50       75      100 Q [l/min]      0       25       50      75      100 Q [l/min]
                          I  = 625 mA (12 VDC)
                           G
                          I  = 305 mA (24 VDC)
                           G                                                                                                        p  = f (n)  Pressure adjustment characteristics      Δp = f (Q)  Leakage volume flow characteristics
                          L15 / 17, 50 °C                                                                                            red
                                                                                                                                                                                                 3
                          I  = 950 mA (12 VDC)                                                                                                Measured at Q = 1 l/min                       Q [cm /min]
                           G
                          I  = 450 mA (24 VDC)             ACTUATION                                                                    p [%]                                             250  K0223
                           G
                          L15 / 17, 70 °C                   Actuation          Proportional solenoid, wet pin push                   100  K0226                                           200
                          I  = 910 mA (12 VDC)                                 type, pressure tight                                   80
                           G                                                                                                                                                              150
                          I  = 420 mA (24 VDC)
                           G                                Execution          MKY45 / 18x60 (data sheet 1.1-183)                     60                                                  100
       Standard nominal   9 W, 15 W, 17 W                                      MKU45 / 18x60 (data sheet 1.1-184)                     40
       power                                                Connection         Cable gland for cable Ø 6,5…14 mm                                                                           50
       Temperature class  Nominal power 9 W: T1…T6                                                                                    20                                                    0  0  50  100  150  200  250  300  350 p [bar]
                          Nominal power 15 W / 17 W: T1…T4  Attention!  The UL execution is always supplied without cable              0  0    20     40     60     80    100  I [%]
                                                                    gland
       Note!   Other electrical specifications see data sheet 1.1-183
               and 1.1-184



                         www.wandfluh.com  Illustrations are not binding  Data subject to change  2/4  Edition: 21 21  2.3-536 E                      www.wandfluh.com  Illustrations are not binding  Data subject to change  3/4  Edition: 21 21  2.3-536 E