Pressure reducing valves                                                                 Pressure reducing valves
                                                                                           Pressure reducing valve

 2
 CHARACTERISTICS  oil viscosity υ = 30 mm /s  Pressure reducing valve
 p  = f (Q)  Pressure volume flow characteristics  p  = f (Q)  Pressure volume flow characteristics  Flange- and sandwich construction
 red
 red
    (Maximal adjustable pressure)     (Minimal adjustable pressure)   NG10
    ∗ Consumption resistance dependent on system  • Pilot operated  ISO 4401-05
 p [bar]  p [bar]  • Q max    = 80 l/min
 250  K0523  25  K0522  • p max    = 400 bar
 200  20    • p N red max  = 350 bar
 P N red = 200 bar
 150  P N red = 160 bar  15
 P N red = 31.5/63/125/  DESCRIPTION           FUNCTION                           APPLICATION
 100  P N red = 125 bar  10              160/200 bar  Flange or sandwich type pilot operated 3-way   The spool, located in the pilot operated main   Pressure reducing valves are used for keeping
  ∗
 50  P N red = 63 bar  5  pressure reducing valve. Screw-in cartridge   section of the valve, is held in the reset position   the pressure constant in a consumer, irrespec-
 P N red = 31,5 bar  M22x1,5 in according with ISO 7789. The   by a spring. The connection to the consumer   tive of pressure fluctuations on the supply side.
 0  0       valve reduces the inlet pressure to a preset   is fully open. With the pilot stage which is   If several consumers are used, the reduced
 30  24  18 12   6   0   6   12  18 24 30  30  24  18 12   6   0   6   12  18 24 30  output pressure. The integrated pressure relief   designed as relief valve, reduced pressure is   pressure can be set individually with the aid if
 A     T  Q [l/min]  P   A  A     T  Q [l/min]  P   A  function prevents the reduced pressure from   adjustable. It opens when the set value is rea-  one pressure control valve for each consumer.
 p  = f (n)  Pressure adjustment characteristics  ∆p = f (Q)  Pressure loss/flow characteristics  being exceeded as a result of external forces.   ched. As a result, a pilot volume flows through   Generally speaking, pressure control valves
                                               the nozzle in the spool. The resultant pressure
                                                                                  are used for reducing a hydraulic pressure to
            Two types of setting and three pressure stages
 red
    [at Q = 0 l/min (static)]     over non-return valve
            are available. A pressure gauge connection is   difference displaces the spool towards the   a lower level. The integrated pressure relief
 p [bar]  p [bar]  provided in the reduced connection. A bypass   spring. The volume flow is throttled in the valve   function obviates the need for any additional
 250  K0521  10  K0524  non-return valve plate for the flange valve – for   inlet and the reduced pressure is controlled. If   pressure relief valve in the reduced pipe. Di-
 P N red = 200 bar  free flow from A to P – can be ordered sepa-  forces acting on the actuator allow the reduced   rectly operated pressure reducing valves also
 200  8
 P N red = 160 bar  rately. The flange valve body is painted, the   pressure to exceed the set value, the spool is   keep the reduced pressure stable, even under
 150  P N red = 125 bar  6  sandwich plates  are phosphatised.  displaced until the valve inlet closes and the   very difficult operating conditions.
 100  4                                        reduced pressure port is being connected to
                                               tank. The pressure increase is then limited.
 P N red = 63 bar
 50  2
 P N red = 31,5 bar
 0  0       TYPE CODE
 0  2  4  6  8  10  12  n [-]  0  6  12  18  24  30  Q [l/min]
                                                                                 M  V      A10  -      -      #
 TYPES / DIMENSIONS
 Flange construction  Pressure reducing valve
 ADRVdN6  ADRVdN6  Pilot operated
            Type of adjustment      Kay         S
                                    Control knob   D
            Flange design           F
            Sandwich design         S
 A  P  T B
            International standard interface ISO, NG10
 Sandwich construction  Type list / function   Flange design      Sandwich design
 ADRVd6   ADRVdA6   ADRVdB6        P → A   P/A      in P      P
                                                    in A      A
 A  P red  T B  A  P T B  A P T  B  ADRVd6          in B      B
 ADRVdA6    Pressure range p N red       63 bar       63
                                    160 bar         160
                                    350 bar         350

 A  P  T B  A red P T B  A P T  B red  Design-Index (Subject  to change)


 PARTS LIST
   Position   Article   Description  GENERAL SPECIFICATIONS      HYDRAULIC SPECIFICATIONS
            Description       Pilot operated pressure control valve  Fluid             Mineral oil, other fluid on request
   40   153.1601   Hexagonal nut 0,5D M12  Nominal size   NG10 according to ISO 4401-05  Contamination efficiency   ISO 4406:1999, class 18/16/13
   50   246.2117   Zyl. screw M5 x 16 DIN912  Construction   Flange or Sandwich        (Required filtration grade ß6…10≥75)
                                                                                       refer to data sheet 1.0-50/2
                              4 mounting holes for zyl. screws M6
            Mounting
   60   246.2146   Zyl. screw M5 x 45 DIN912  Spindle not secured against      or double ended screws M6  Viscosity range   12 mm /s…320 mm /s
                                                                                                     2
                                                                                            2
   70   238.2406   Plug VSTI G1/4"-ED  unscrewing  Connection   Threaded connection plates   Fluid temperature   -20…+70 °C
   90   160.2093   O-Ring ID 9,25 x 1,78     Multi-flange subplates  Peak pressure     p max   = 400 bar
   100   114.1202   Knob  For sandwich red. pressure     Ambient temperature   Longitudinal stacking system  Red. nominal pressure   p N red   = 63 bar, p N red  = 160 bar
                                                                                           = 350 bar
                              -20…+50 °C
                                                                                       p

 in B the adjusting parts are
                                                                                        N red
   110   154.7100   Cap nut  on A-side  Mounting position   any  Opening pressure      p    = 0,8 bar
                                                                                        ö
            Fastening torque   M = 9,5 Nm (qual. 8.8) for fastening screws  to  non-return valve
                                D
 ACCESSORIES                  M = 50 Nm for screw-in cartridge   Volume flow           Q = 0…80 l/min
                                D
 Threaded connection plate and multi-flange subplates   Reg. 2.9  Weight   Depending on the type  2,89…3,09 kg  For futher hydraulic specifications see data sheet 2.2-530.
 Technical explanation see data sheet 1.0-100  Bypass non-return valve ADRVP6
 A  P  T B
 Wandfluh AG   Tel.  +41 33 672 72 72   E-mail:  sales@wandfluh.com   Illustrations not obligatory   Data sheet no.   Wandfluh AG   Tel.  +41 33 672 72 72   E-mail:  sales@wandfluh.com   Illustrations not obligatory   Data sheet no.
 Postfach   Fax  +41 33 672 72 12   Internet:  www.wandfluh.com   Data subject to change   2.2-650E 2/2   Postfach    Fax  +41 33 672 72 12   Internet:  www.wandfluh.com   Data subject to change   2.2-660E 1/2
 CH-3714 Frutigen                   Edition 21 30  CH-3714 Frutigen                                      Edition 05 04
 A  P red  T B  A  P T B  A P T  B                                                                          Page 927
 A  P  T B  A red P T B  A P T  B red
   922   923   924   925   926   927   928   929   930   931   932