                                                                                  Digital amplifier module SD7                                                                                                Digital amplifier module SD7
                                                                                      Digital amplifier module
       CONNECTOR WIRING DIAGRAM / PIN ASSIGNMENT                                                                                   Command value scaling                                Mode of operation «Command value bipolar (2-sol)»
                                                                                                                                   The command value can be applied as a voltage, current or digital si-  Dependent on a bipolar command value signal (voltage), according to
       USB-interface, USB Type B X2                      Basic amplifier              - Basic Analog  - Basic fieldbus             gnal, or via fieldbus. For every command value, the input utilised can   the signal level one of the two solenoids is driven. The switching thres-
                                                                                               - Enhanced

                                                                                                                                               B
                                                                                                                                         A
                  1  =  VBUS                               1  =  Digital input 1                                                   be selected. The scaling takes place via the parameters «Interface»   hold between the two solenoids as standard is at 0V (e.g. -10….+10V
                      5
                  9 2  =  D -  6  1                        2  =  Digital input 2                                                   and «Reference». Furthermore every command value can be monito-  correspond to -100….+100 % command value, -100…0 % command
                                                                                                          A
         3   2    8   4 3  7  2 3                                                               1 2 3 4  17 18 19 20
                                                                                                          B
         4   1    7 3  =  D+  8  4                         3  =  Digital output 1               5 6 7 8  21 22 23 24               red for a cable break (except for voltage and digital signal). For every   value correspond to Imin….Imax solenoid driver 2, 0….+100 % com-
                      2
                  6      9                                 4  =  Digital output 2                                                  command value a dead band can also be set. Optionally one can ope-  mand value correspond to Imin….Imax solenoid driver 1).
                  4  =  GND  5
                      1
                                                           5  =  Supply voltage +                                                  rate with two command values. The characteristic of these command
                                                                                                                                                           17 18 19 20
                                                                                                                                                      1 2 3 4
                                                                                                                          1 2 3 4
                                                                                                                               17 18 19 20
       The parameterisation cable is not included in the delivery    6  =  Supply voltage 0 VDC                           5 6 7 8  21 22 23 24 values can be adjusted.  5 6 7 8  21 22 23 24
       (commercially available USB cable, plug type A to plug type B)    7  =  Stabilised output voltage
                                                           8  =  Analog ground                                                     Fixed command values
                                                           9  =  Analog input 1+                                                   •   For the Basic amplifier, 3 fixed command values are available,
                                                         10  =  Analog input 1 -                                                       which can be selected via 2 digital inputs.                      Changeover
                                                                                                                                                                                                         threshold
       Device receptacle CANopen, J1939 (male) X4 (option)  11  =  Analog input 2+                FUNCTION  L                      •   For the Enhanced amplifier, 7 fixed command values are avai-    between the two
                                                                                                                                                                                                         solenoids
                                                         12  =  Analog input 2 -                 ERROR  SUPPLY  FIELDBUS X4  ERROR  FUNCTION  SUPPLY  lable, which can be selected via 3 digital inputs.   
                                                                                                                                                        FUNCTION
                                                                                                                                                         SUPPLY
                                                                                                                                                       ERROR
    5         1   1  =  Reserved     6 =  Reserved       13  =  Output solenoid driver 2 +                                      FIELDBUS X4                 FIELDBUS X4
 9     6                                                 14  =  Output solenoid driver 2 -                                         Command value generator                                                                  Command value
 3  2  4      2   2  =  CANLow       7 =  CANHigh
 8  3  7      3   3  =  CANGnd       8 =  Reserved       15  =  Output solenoid driver 1 +                                         For each solenoid output two linear ramps for up and down are avai-                      Analogue value
                                                                                                                                                       USB
                                                                                                                                                      9 10 11 12 25 26 27 28
 4  1  7  2  8  4  4  =  Reserved    9 =  Reserved       16  =  Output solenoid driver 1 –       USB                       USB     lable which can be adjusted separately.
                                                                                                          C
 6     9                                                                                        9 10 11 12 25 26 27 28    9 10 11 12 25 26 27 28     13 14 15 16 29 30 31 32
    1         5   5  =  CANShield                        21  =  HART (option) Analog input 3 +  13 14 15 16 29 30 31 32
                                                                                                                          13 14 15 16 29 30 31 32
                                                         22  =  HART (option) Analog input 3 -            D                        HOLD command value (fieldbus only)                   Mode of operation «Command value unipolar (2-sol with DigInp)»
                                                                                                                                   If via Profibus DP the device is put into the «HOLD» state, the respec-  Dependent on a unipolar command value signal (voltage, current), the
                                                                                                                                         C
                                                                                                                                               D
       The mating connector (plug female, DSUB, 9-pole) is not included                                                            tive command value is activated.                     solenoid is driven by solenoid driver 1, when the selected digital input
       in the delivery.                                                                                                                                                                 is «not activated», resp. the solenoid by the solenoid driver 2, when the
                                                                                                                                   Valve type                                           selected digital input is «activated» (e.g. 0….10V correspond to 0….100
                                                         Additional                   Enhanced amplifier                           Here the mode of operation is set. It is also possible to select whether   % command value, 0....100 % command value correspond to Imin….
                                                         Enhanced amplifier           with HART                                    proportional or switching solenoids are to be controlled.  Imax solenoid driver 1 or 2).
       Device receptacle Profibus (female) X4 (option)
                                                         17  =  Digital input 3       17  =  Analog output +                       Mode of operation «Command value unipolar (1-sol)»
              5   1  =  Reserved     6 =  VP             18  =  Digital input 4       18  =  Analog output -                       Dependent on a unipolar command value signal (voltage, current), the
                         1
       9          6 2  =  Reserved   7 =  Reserved       19  =  Digital input 5       19  =  Digital input 3                       solenoid is driven (e.g. 0...10V correspond to 0...100 % command va-
                         2
 3  2  8      4 3  7 3  =  RxD / TxD - P   8 =  RxD / TxD - N  20  =  Digital input 6  20  =  Digital input 4                      lue, 0...100 % command value correspond to Imin...Imax solenoid dri-
                         3
 4  1  7      2   8 4  =  Reserved   9 =  Reserved       21  =  Digital input 7       21  =  Analog input 3 + HART                 ver 1).
                         4
       6          9                                      22  =  Digital input 8       22  =  Analog input 3 - HART
                         5
              1   5  =  DGND
                                                         23  =  Digital output 3      23  =  Analog input 4 +
       The mating connector (plug male, DSUB, 9-pole) is not included    24  =  Digital output 4  24  =  Analog input 4 -
       in the delivery.                                  25  =  Analog input 3 +                                                                                                                                            Command value
                                                         26  =  Analog input 3 -
                                                         27  =  Analog input 4 +                                                                                                                                             Analogue value
                                                         28  =  Analog input 4 -
                                                         29  =  Digital ground                                                                                                                      Changeover between the two
                                                         30  =  Analog ground                                                                                                                   solenoids by means of the selected digital input
                                                         31  =  Stabilised output voltage                                                                              Command value
                                                         32  =  Analog output
                                                                                                                                                                        Analogue value  Signal recording
                                                                                                                                                                                        The SD7 amplifier module has a signal recording function. This, by
       FUNCTION DESCRIPTION                                                                                                                                                             means of PASO, enables the recording of various system signals, such
       The amplifier module can be parameterised by means of the parame-  enables the setting of the most important parameters by means of ro-  Mode of operation «Command value unipolar (2-sol)»  as command value, solenoid currents, etc., which can be represented
       terisation software «PASO» through the USB-interface. In addition,   tary selector switch and push-buttons and therefore makes a com-  Dependent on a unipolar command value signal (voltage, current), ac-  on a common time axis.
       the parameterisation software makes a data analysis possible. Optio-  missioning of the amplifier module possible without a PC.  cording to the signal level one of the two solenoids is driven. The swit-
       nally the amplifier module is equipped with a manual operation, which                                                       ching threshold between the two solenoids as standard is in the middle   Solenoid driver
                                                                                                                                   of the values range of the command value signal (e.g. 0….10V corre-  Two Pulse-Width-Modulated current outputs are available. To each out-
                                                                                                                                   spond to -100….+100 % command value, -100....0 % command value   put, a dither signal is superimposed, whereas dither frequency and
                                                                                                                                   correspond to Imin….Imax solenoid driver 2, 0….+100 % command   dither level can be adjusted separately. For each output, the minimum
                                                                                                                                                                                        (Imin) and maximum (Imax) current can be adjusted separately. The
                                      HOLD         Fieldbus only                                                                   value correspond to Imin….Imax solenoid driver 1).   solenoid outputs can also be configurated as switching outputs. The-
                                     Command                                          Solenoid output                                                                                   rewith for each output a power reduction can be adjusted separately.
                                       value                                  Solenoid
                                                                               driver 1
                                                                                      Current measurement
                                                                                                                                                                                        Optimisation of characteristic curve
       Command                                                                                                                                                                          A characteristic curve adjustable per solenoid «Command value input
       value 1                                                                                                                                     Changeover                           – solenoid current output» enables an optimised (e.g., linearised) cha-
               Command         Fixed         Command                      DigInp                                                                    threshold                           racteristic of the hydraulic system.
       Command  value         command         value          Valve                                                                                between the two
       value 2  Scaling        values        generator       type           Enable  Error                                                           solenoids
                                                                                                                                                      
                                                                                      Solenoid output                                                                  Command value
           DigInp          DigInp        DigInp        DigInp                 Solenoid
                                                                               driver 2  Current measurement                                                            Analogue value
            Selection Error   Number        Enable       Solenoid 2
                                                                          DigInp
                                                                            Enable  Error
       Wandfluh AG        Tel.  +41 33 672 72 72   sales@wandfluh.com     Illustrations not obligatory   Data sheet no.            Wandfluh AG         Tel.  +41 33 672 72 72   sales@wandfluh.com     Illustrations not obligatory   Data sheet no.
       Postfach           Fax  +41 33 672 72 12   www.wandfluh.com        Data subject to change   1.13-101E 4/10                  Postfach            Fax  +41 33 672 72 12   www.wandfluh.com        Data subject to change   1.13-101E 5/10
       CH-3714 Frutigen                                                                            Edition 23 02                   CH-3714 Frutigen                                                                             Edition 23 02
       Page 734
   729   730   731   732   733   734   735   736   737   738   739