Page 1034 - Softbound_Edition_19_en
P. 1034

Proportional pressure reducing valve
                                                                         Proportional pressure reducing valve                                                                                          Proportional pressure reducing valve


       CERTIFICATES                                        SYMBOL                                                                  PERFORMANCE SPECIFICATIONS  EXECUTION L9 (MEASURED AT 40 °C)
                                                                                                                                                    2
                    Surface   Mining   Standard  M248                                                                              Oil viscosity u = 30 mm /s
                                        -25 °C   Electronic      (A) 1                                                              p =f (Q)  Pressure volume flow characteristic        p =f (Q)  Pressure volume flow characteristic
                                        to…                                                                                                   Maximal adjustable pressure                          Minimal adjustable pressure
       ATEX            x        x         x        x                                                                                   p [bar]                                              p [bar]
       IECEx           x        x         x        x                                                                                  300  K4167                                          100  K4168
                                                             (P) 2  (T) 3                                                                                                                  90
       CCC             x        x         x        x                                                                                  250                                                  80
       EAC             x        x         x        x                                                                                  200                                   p N red  = 200 bar  70
                                                                                                                                                                                           60
                                                                                                                                      150                                                  50
       Australia       x        x         x                                                                                           100                                   p N red  = 115 bar  40
                                                                                                                                                                                           30
       MA                       x         x        x                                                                                  50                                    p N red  = 80 bar  20
                                                                                                                                                                                           10
       UL / CSA        x                  x                                                                                            0                                    p N red  = 20 bar  0
                                                                                                                                        25  20  15  10  5  0  5  10  15  20  25              25  20  15  10  5  0  5  10  15  20  25
       The certificates can be found on www.wandfluh.com                                                                                       A  T   Q [l/min]  P  A                             A  T   Q [l/min]  P  A

       GENERAL SPECIFICATIONS                              HYDRAULIC SPECIFICATIONS                                                 p =f (I)  Pressure adjustment characteristics
                                                                                                                                              Up to I  = 40 % slightly increased hysteresis
       Designation        Proportional pressure reducing valve  Working pressure  p  = 350 bar                                                     G
                                                                                max
       Construction       Direct operated by means of pilot spool  Nominal pressure   Ausführung L9                                    p  [bar]
                                                                                                                                        red
       Mounting           Screw-in cartridge construction   range              p  = 20 bar, 80 bar, 115 bar, 200 bar                  200  K4169                           p N red  = 200 bar
                                                                                                                                      180
                                                                                N
       Nominal size       M22 x 1,5 according to ISO 7789                      Ausführung L15 / 17                                    160
                                                                                                                                      140
       Actuation          Proportional solenoid                                p  = 20 bar, 95 bar, 135 bar, 235 bar                  120                                  p N red  = 115 bar
                                                                                N
                                                                                                                                      100
       Ambient temperature  Operation as T6                 Minimum adjustable   < 1 bar                                              80                                   p N red  = 80 bar
                          -25…+40 °C (L9)                   pressure                                                                  60
                                                                                                                                      40
                          Operation as T4                   Volume flow range  See characteristic                                     20 0                                 p N red  = 20 bar
                          -25…+70 °C (L9)                   Leakage oil        at p  = 350 bar                                          0   10  20  30  40  50  60  70  80  90  100  I [%]
                                                                                  sys
                          -25…+70 °C (L15 / L17)                               < 30 ml/min for p N red  = 20, 80 (95), 115
       Weight             1,95 kg                                              (135) bar
       MTTFd              150 years                                            < 50 ml/min for p N red  = 200 (235) bar            PERFORMANCE SPECIFICATIONS  EXECUTION L15 / L17 (MEASURED AT 50 °C)
                                                            Hysteresis         ≤ 5 % at optimal dither signal                      Oil viscosity u = 30 mm /s
                                                                                                                                                    2
                                                            Repeatability      ≤ 2 % at optimal dither signal
                                                            Fluid              Mineral oil, other fluid on request                  p =f (Q)  Pressure volume flow characteristic        p =f (Q)  Pressure volume flow characteristic
                                                                                                                                                                                                   Minimal adjustable pressure
                                                                                                                                              Maximal adjustable pressure
                                                            Viscosity range    12 mm /s…320 mm /s
                                                                                            2
                                                                                   2
       ELECTRICAL SPECIFICATIONS                            Temperature range   Operation as T6                                        p [bar]                                              p [bar]
                                                                                                                                         K4209
                                                                                                                                                                                              K4168
                                                            fluid              NBR -25…+40 °C (L9)                                    300                                                 100
       Protection class   IP65 / 66 / 67                                       FKM -20…+40 °C (L9)                                    250                                                  90
                                                                                                                                                                                           80
       Relative duty factor  100 % DF                                          Operation as T4                                        200                                   p N red  = 235 bar  70
                                                                                                                                                                                           60
       Voltage tolerance  ± 10 % with regard to nominal voltage                NBR -25…+70 °C (L9 or L15 / L17)                       150                                                  50
                                                                                                                                                                                           40
       Standard nominal   12 VDC, 24 VDC                                       FKM -20…+70 °C (L15 / L17)                             100                                   p N red  = 135 bar  30
                                                                                                                                                                            p N red  = 95 bar
                                                                                                                                                                                           20
       voltage                                                                 FKM -20…+70 °C (L9)                                    50 0                                  p N red  = 20 bar  10 0
       Limiting current at… °C L9, 40 °C                    Contamination      Class 18 / 16 / 13                                       25  20  15  10  5  0  5  10  15  20  25              25  20  15  10  5  0  5  10  15  20  25
                          I  = 625 mA (12 VDC)              efficiency                                                                         A  T   Q [l/min]  P  A                             A  T   Q [l/min]  P  A
                           G
                          I  = 305 mA (24 VDC)              Filtration         Required filtration grade ß 6…10 ≥ 75,
                           G
                          L15 / 17, 50 °C                                      see data sheet 1.0-50
                          I  = 950 mA (12 VDC)                                                                                      p =f (I)  Pressure adjustment characteristics
                           G
                          I  = 450 mA (24 VDC)                                                                                                Up to I  = 40 % slightly increased hysteresis
                                                                                                                                                   G
                           G
                          L15 / 17, 70 °C                                                                                              p  [bar]
                          I  = 910 mA (12 VDC)             ACTUATION                                                                  250  red K4210                       p N red  = 235 bar
                           G
                          I  = 420 mA (24 VDC)              Actuation          Proportional solenoid, wet pin push                    225
                           G                                                                                                          200
       Standard nominal   9 W, 15 W, 17 W                                      type, pressure tight                                   175
       power                                                Execution          MKY45 / 18x60 (data sheet 1.1-183)                     150                                  p N red  = 135 bar
                                                                                                                                      125
       Temperature class  Nominal power 9 W: T1…T6                             MKU45 / 18x60 (data sheet 1.1-184)                     100                                  p N red  = 95 bar
                                                                                                                                      75
                          Nominal power 15 W / 17 W: T1…T4  Connection         Cable gland for cable Ø 6,5…14 mm                      50                                   p N red  = 20 bar
                                                                                                                                      25
                                                                                                                                       0
       Note!   Other electrical specifications see data sheet 1.1-183   Attention!  The UL execution is always supplied without cable   0   10  20  30  40  50  60  70  80  90  100  I [%]
               and 1.1-184                                          gland
                         www.wandfluh.com  Illustrations are not binding  Data subject to change  2/4  Edition: 21 21  2.3-627 E                      www.wandfluh.com  Illustrations are not binding  Data subject to change  3/4  Edition: 21 21  2.3-627 E
       Page 1034